NOTE: If you are using the VF feature, run the configDownload -vf command before
running the configUpload command in order to restore the logical switch configuration.
2. Enter the configDownload command.
Server Name or IP Address [host]: 123.123.123.123
nl
User Name [None]: Admin24
nl
File Name [config.txt]: config-switch.txt
nl
Password: xxxxxxxx
nl
download complete
nl
switch:admin>
3. Reboot the DC SAN Director.
Configuring the new chassis serial number
To configure a new chassis serial number:
1. Open a CLI session (Telnet or serial) to the DC SAN Director and log in as root:
The root and factory account disclaimer is displayed.
Log in using Telnet.
Use the IP address of the DC SAN Director through Telnet and log in as root.
Fabric OS (rsl8-st03-dcx-1)
login: root
Password:
Disclaimer for Root and Factory Accounts Usage!
This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.
Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.
Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.
rsl8-st03-dcx-1:root>
2. Change the factory serial number to the serial number of the new chassis:
a. Enter the fruInfoSet chassis 1 command at the prompt.
b. Enter the OEM serial number, if any, at the SN prompt.
c. Enter the chassis serial number at the Chassis SN: prompt.
Replacing the DC SAN Director chassis 89