Brocade iSCSI Gateway Service Administrator's Guide - Supporting Fabric OS v5.3.0 (53-1000440-01, June 2007)
iSCSI Gateway Service Administrator’s Guide 37
Publication Number: 53-1000440-01
Creating an iSCSI FC zone
4
PortSymb: [23] "iSCSI Virtual Initiator"
NodeSymb: [51] "IPAddr: 30.0.127.33 Slot/Port: 3/ge3 Logical pn: 43"
Fabric Port Name: 00:00:00:00:00:00:00:00
Permanent Port Name: 50:06:06:9e:00:15:63:18
Port Index: 43
Share Area: No
Device Shared in Other AD: No
N 012c00; 3;50:06:06:9e:00:15:63:20;50:06:06:9e:00:15:63:21; na
FC4s: FCP
PortSymb: [23] "iSCSI Virtual Initiator"
NodeSymb: [51] "IPAddr: 30.0.127.34 Slot/Port: 3/ge4 Logical pn: 44"
Fabric Port Name: 00:00:00:00:00:00:00:00
Permanent Port Name: 50:06:06:9e:00:15:63:20
Port Index: 44
Share Area: No
Device Shared in Other AD: No
N 012d00; 3;50:06:06:9e:00:15:63:28;50:06:06:9e:00:15:63:29; na
FC4s: FCP
PortSymb: [23] "iSCSI Virtual Initiator"
NodeSymb: [51] "IPAddr: 30.0.127.35 Slot/Port: 3/ge5 Logical pn: 45"
Fabric Port Name: 00:00:00:00:00:00:00:00
Permanent Port Name: 50:06:06:9e:00:15:63:28
Port Index: 45
Share Area: No
Device Shared in Other AD: No
N 012e00; 3;50:06:06:9e:00:15:63:30;50:06:06:9e:00:15:63:31; na
FC4s: FCP
PortSymb: [23] "iSCSI Virtual Initiator"
NodeSymb: [51] "IPAddr: 30.0.127.36 Slot/Port: 3/ge6 Logical pn: 46"
Fabric Port Name: 00:00:00:00:00:00:00:00
Permanent Port Name: 50:06:06:9e:00:15:63:30
Port Index: 46
Share Area: No
Device Shared in Other AD: No
N 012f00; 3;50:06:06:9e:00:15:63:38;50:06:06:9e:00:15:63:39; na
FC4s: FCP
PortSymb: [23] "iSCSI Virtual Initiator"
NodeSymb: [51] "IPAddr: 30.0.127.37 Slot/Port: 3/ge7 Logical pn: 47"
Fabric Port Name: 00:00:00:00:00:00:00:00
Permanent Port Name: 50:06:06:9e:00:15:63:38
Port Index: 47
Share Area: No
Device Shared in Other AD: No
The Local Name Server has 11 entries }
To display the FC target WWNs for switches other than the Brocade 48000, telnet into that
switch and run the nsShow command.
5. Save the WWN information, which you will use for the zoneCreate command.
At this point you are ready to create the iSCSI gateway service zone with FC targets and initiators as
members of the zone. To simplify the process of creating the zone, begin by creating a zone alias. A
“zone alias” is a logical group of WWNs or ports, which eliminates the need for long lists of
individual zone member names. For more information about zone aliases, see “Creating and
Managing Zone Aliases” in the Fabric OS Administrator’s Guide.