HP NetRAID Installation and Configuration Guide
Chapter 8 Upgrading to an HP NetRAID-3Si or HP NetRAID-1Si Adapter
111
Plug in BBU connector
Battery Backup Unit (BBU)
J21
Figure 8-3. Plug in Battery Backup Unit on HP NetRAID-3Si Board
3. Connect all SCSI cables to the new adapter, as described in Step E of
Chapter 5.
4. Close the HP NetServer panel or replace the HP NetServer cover, plug in
the power cord(s), and turn on power to the HP NetServer.
5. After you see the flashing message "Firmware Initializing," you
will see this message:
Configuration of NVRAM and drives mismatch for
Host Adapter
X
Run View/Add Configuration option of Configuration
Utility
Press any key to enter the Configuration Utility.
This message tells you that the configuration information stored in the drives
(the correct configuration) does not match the configuration information stored
in NVRAM on the newly installed HP NetRAID Series adapter.
NOTE If there is more than one HP NetRAID Series adapter
(including any integrated HP NetRAID controller), the
message tells you which adapter number has the mismatch. Be
sure to note which adapter needs to be reconfigured.