HP NetRAID Installation and Configuration Guide
Appendix D Cabling Diagrams
186
Duplex Cabling to Dual-Bus HP NetServer Rack Storage/8
HP NetServer LXr HP Rack Storage/8
(Dual Bus)
HP NetRAID-3Si
Channel 1
HP NetRAID-3Si
Channel 0
Option Switches Set to
Bus 1
Input
Bus 2
Input
Single-ended
Terminator on
Bus 2 Output
Single-ended
Terminator on
Bus 2 Output
Figure D-13. Cabling Two External Channels from an HP NetRAID Adapter in
an HP NetServer LXr to a Dual-Bus HP NetServer Rack Storage/8.
(The external connectors for any two channels of an
HP NetRAID or HP NetRAID-3Si adapter can be used.)
Mass Storage Cables
SCSI cables (2.5 m long and not extendible) limit the distance between a storage
unit and its associated server. The HP NetServer Rack Assembly and Cabling
Reference Guide guidelines for rack layouts take this distance limitation into
account.