hp tc4100 netraid-2m config guide for Microsoft NT 4.0 Clusters PDF, 395K, 4/1/2002

tc4100nt2m
Server Configuration
Parameter Specification
Default boot order
IDE CD-ROM, FDD, embedded SCSI A, embedded SCSI B, PCI slot 6, PCI slot
5, PCI slot 4, PCI slot 3, PCI slot 2, PCI slot 1, integrated LAN
Local Storage
Controller Embedded SCSI, or NetRAID-1M
When using the NetRAID-1M, flash it to firmware version H.01.09, obtained
from the HP NetRAID-1M and NetRAID-2M Supplemental CD-ROM.
Driver For embedded SCSI, sym_u3.sys, version 5.09, or later
For NetRAID-1M, mraidnt.sys, version 4.09
(Embedded SCSI driver obtained from M.04.60 Navigator CD-ROM.
NetRAID-1M/2M driver obtained from the HP NetRAID-1M and NetRAID-2M
Supplemental CD-ROM.)
Physical drive location Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives Must be HP
SCSI bus Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs Any
System software
Navigator CD-ROM Version M.04.60, or later
Operating system
Service pack
Microsoft Window NT
â
Server 4.0, Enterprise Edition
SP5 or
SP6a and Microsoft
â
hotfix Q316743.
Please refer to the Microsoft
â
product support article at:
http://support.microsoft.com/default.aspx?scid=KB;EN-
US;q316743&ID=KB;EN-US;q316743
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power
cabling diagram on page 6.
Shared Storage Configuration
Parameter Specification
Controller
Model HP NetRAID-2M Controller, Model P3411B, or P3475B
Number of controllers One or two
BIOS Disabled
Firmware Version H.01.09
(firmware obtained from the HP NetRAID-1M and NetRAID-2M Supplemental
CD-ROM)
Driver Mraidnt.sys, version 4.09
(driver obtained from the HP NetRAID-1M and NetRAID-2M Supplemental
CD-ROM)
NetRAID Assistant Version B.01.04, or later
(software obtained from the Navigator CD-ROM, version M.04.60)
SCSI ID 6, 7
4/1/02 2