hp tc4100 netraid-2m config guide for Microsoft NT 4.0 Clusters PDF, 395K, 4/1/2002

tc4100nt2m
Shared Storage Configuration
Parameter Specification
Channels 0, 1
RAID levels 1, 5, 10, 50
Logical disks One per RAID array
Eight, maximum, per cluster
Configuration options Cluster mode on
Cache write policy to Write thru
Enclosure
Disk drives Any HP drive supported by storage enclosure. Any combination of HP disk
models is allowed in an array, on a SCSI channel, or in a cluster.
Number of cabinets One or two per NetRAID-2M controller (up to four per cluster)
Model Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID 5 (fixed)
Disk SCSI IDs 0–3, 8–15 (fixed)
Cables
SCSI Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See SCSI cabling diagram on page 5.
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power
cabling diagram on page 6.
Intra-Cluster (Heartbeat) LAN Configuration
Parameter Specification
Network
Connection HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication. It may
not be used for client communication.
NIC
Quantity One
Model Integrated NIC, HP 10/100 IPSec 3DES, Model P3492A, or any LAN adapter
that is on both the HP Tested Products List and the Microsoft
®
Hardware
Compatibility List
Driver For integrated NIC or P3492A, latest version from Navigator CD-ROM or HP
technical support web site.
For other NICs, any vendor-supported driver.
4/1/02 3