HP Netserver LC 3 NetRAID-3Si Installation Guide

2
SPU
Model HP NetServer LC3
Clock speed 400, 450, 500, 550 MHz.
No. of CPUs 1 – 2, but must be the same number of CPUs in each server
BIOS version 4.06.23 PQ
CPU cache Any size
RAM 64 MB minimum. Must be HP.
Local storage Internal or external, using any controller. Must use HP disks. See
Local
Storage below.
I/O slots: P5 - Shared storage controller
P4 – Intra-cluster (Heartbeat) LAN
P1 – Client LAN
All others - Any other plug-in cards.
Local Storage
Physical drive location SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12)
Disk drives Must be HP
Controller
May use SPU embedded controller, NetRAID-3Si, or any controller (any
number, manufacturer or driver) in any available I/O slot.
May not use NetRAID-1 or NetRAID-3.
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed
Shared Storage
Controller
Model HP NetRAID 3Si Adapter D5955A
No. of controllers 1
Firmware W.01.20 or later
BIOS B.01.10 or later
Driver 2.22 or later
NetRAID Assistant A.01.15 or later
SPU I/O slot P6
SCSI ID 6, 7
Channels 0, 1, 2
RAID level 1, 5, 10, 50
Logical disks 1 per RAID array
Configuration
options:
Cluster mode on
Cache write-policy to write-thru
Set any other options as you prefer