HP NetRAID-4M and RS/12 Cluster Install Guide for Windows 2000 Advanced Server Clusters
HP NetRAID-4M Cluster Services Installation Guide Cluster Software Components and Quorum
26
3.4 Configure the Cluster Shared Quorum
Using the NetRAID-4M FAST Utility
1. On Server A, from the Windows 2000 Start button start the NetRAID-4M FAST utility.
2. Verify that the Available Controllers window displays the local HP NetRAID-4M and click
Open.
3. Expand the Controller View window.
Create Disksets
NOTE A diskset cannot span disks across multiple controllers.
4. From the Disk (Physical Drv) menu, click on the Manage Disksets button.
5. To create a shared quorum drive of two mirrored hard disks, from the Non-Member Disks
listing, select two Disk IDs and then click the Create Diskset …>> button.
In the following example, the first drive in each of two RS/12s was selected:
0:00:0 and 2:00:0.
To create a shared quorum drive on a RAID-5 set, select 3 or more Disk ID’s from the
Non-Member Disks listing, then click the Create Diskset …>> button.
NOTE HP recommends creating a fault-tolerant RAID type, such as RAID-1 or RAID-5
for the shared quorum drive.