Integrated HP NetRAID Controller Config. Guide

Chapter 4 Planning
29
NOTE SCSI ID 7 is reserved for the integrated HP NetRAID
controller.
For internal mass storage in HP NetServer LH 3000/3000r,
LH 6000/6000r, and LT 6000r, SCSI ID 5 is reserved for the
SAF-TE (SCSI Access Fault-Tolerant Enclosure) processor
that manages the hot-swap mass storage cage.
For an external mass storage enclosure with a SAF-TE
processor, a SCSI ID is reserved for that processor. The
number of the reserved SCSI ID varies with the type of
external enclosure.
Channels
In this section you determine which physical devices (drives) will connect to each
SCSI channel. As explained in Chapter 1, "Introduction," for each channel, you
have either one internal or one external connection. The integrated HP NetRAID
controller supports both internal and external connectors for Channels 0 and 1,
except in HP NetServer LT 6000r.
SCSI Channels on the HP NetServer
The HP NetServers have two hot-swap mass storage SCSI channels: SCSI A and
SCSI B. HP NetServer LH 3/3r and LH 4/4r differ from other HP NetServers
with regard to these channels. Table 4-1 summarizes the differences.