Integrated HP NetRAID Controller Config. Guide
Chapter 4 Planning
32
• HP NetServer LH 3000/3000r and LH 6000/6000r:
◊ SCSI A has these characteristics:
∗ By default, SCSI channel A is connected to the internal hot-swap
mass storage cage that was shipped with your HP NetServer.
∗ By default, the integrated HP NetRAID subsystem is enabled for
SCSI A.
◊ SCSI B has these characteristics:
∗ By default, SCSI channel B is not connected. An optional internal
hot-swap mass storage cage or external enclosure could be
connected to it. It could also be connected to the second bus of an
internal hot-swap mass storage cage that has an accessory duplex
board installed.
∗ By default, the integrated HP NetRAID subsystem is enabled for
SCSI B.
◊ SCSI SE is for non-hot swap drives. Integrated HP NetRAID does not
control devices on it.
• HP NetServer LT 6000r:
◊ SCSI A has these characteristics:
∗ By default, SCSI channel A is connected to the hot-swap mass
storage cage in your HP NetServer.
∗ By default, the integrated HP NetRAID subsystem is enabled for
SCSI A.
◊ SCSI B has these characteristics:
∗ By default, SCSI channel B is not connected. It is intended for
connection to external devices or an external mass storage
enclosure.
∗ By default, the integrated HP NetRAID subsystem is enabled for
SCSI B.
∗ If integrated HP NetRAID is enabled, you cannot use devices with
multiple LUNs (logical units) on the external channel. An example
of a device with multiple LUNs that you cannot use is an
autoloader tape device. If you want to use a device with multiple