Integrated HP NetRAID Controller Config. Guide
Chapter 5 Configuration
50
3. If a password has been set, provide it when prompted.
4. When the Setup Utility menu is displayed, the settings for the integrated
HP NetRAID controller are:
• Integrated HP NetRAID [Enable/Disable]
This setting enables or disables the integrated HP NetRAID controller
for both SCSI ports. To use the HP NetRAID controller, this setting
must be set to Enable.
• Included SCSI_A Channel [Yes/No]
If the integrated HP NetRAID controller is enabled, this setting
selectively includes or excludes SCSI port A from the HP NetRAID
subsystem.
• Included SCSI_B Channel [Yes/No]
If the integrated HP NetRAID controller is enabled, this setting
selectively includes or excludes SCSI port B from the HP NetRAID
system.
CAUTION If a channel was previously operating in non-RAID SCSI
mode, changing to RAID mode (integrated HP NetRAID
enabled and the channel included) could cause data loss. Be
sure your data is backed up before you change to RAID mode.
If your HP NetServer was previously operating in RAID
mode, changing to non-RAID mode could cause data loss. Be
sure your data is backed up before you change to non-RAID
mode.
NOTE If you enable HP NetRAID for just one SCSI channel, that
becomes the integrated HP NetRAID Channel 0. If you enable
both SCSI channels, SCSI A becomes Channel 0, and SCSI B
becomes Channel 1.
5. If necessary, you can use the Setup utility to change settings such as the
boot order.
6. Press the F10 function key to save and exit.