Integrated HP NetRAID Controller Config. Guide
Chapter 5 Configuration
51
7. In the Setup Configuration dialog box, press the Enter key to answer
"Yes" to the question "Save configuration and exit now?" The HP
NetServer reboots.
8. Go to Step E.
For HP NetServer LH 3000/3000r, LH 6000/6000r, and LT 6000r, Run
Setup Utility
Use the Setup utility to verify HP NetRAID control of SCSI channels A and B
(the default setting) and to verify the boot device priority and the priority of
various hard disk drive controllers within the boot device priority.
Start Setup Utility
1. Turn on power to the HP NetServer and display monitor.
If you receive an error message during the boot process, refer to your
HP NetServer's installation guide, to the online help in Information
Assistant, or to Chapter 11, "Troubleshooting," in this guide. Some
power-up (boot) messages are routine.
NOTE The message "Configuration of NVRAM and drives
mismatch" indicates that configuration information in the
integrated HP NetRAID controller's NVRAM differs from
configuration information of the hard disk drives.
1. Press <Ctrl> <M> to start the HP NetRAID Express Tools
utility.
2. On the Tools Management Menu, choose Configure.
3. On the Configure menu, choose View/Add/Delete
Configuration.
4. View the configuration in NVRAM to decide whether it is
correct. Press Esc. You are asked if you want to save the
configuration.
• If the NVRAM configuration is correct, answer Yes to
save it. Go to Step 7.
• If the NVRAM configuration is not correct, answer No.