Chapter 5 Configuration
54
11. The Embedded LAN and SCSI Settings submenu is displayed. If
HP NetRAID/LVD SCSI is not already highlighted, use the up and down
arrows to highlight it.
Read the values in the brackets to determine whether HP NetRAID is
enabled.
◊ Enable LVD SCSI indicates that LVD SCSI is enabled and
HP NetRAID is disabled. This is the setting for non-RAID operation
of the mass storage connected to SCSI A and B on the I/O board.
◊ Enable HP NetRAID indicates that HP NetRAID is enabled to
provide RAID operation of the mass storage connected to SCSI A and
B on the I/O. This is the default value.
CAUTION If your HP NetServer was previously operating in non-RAID
mode (Enable LVD SCSI), changing to RAID mode (Enable
HP NetRAID) could cause data loss. Be sure your data is
backed up before you change to RAID mode.
If your HP NetServer was previously operating in RAID mode
(Enable HP NetRAID), changing to non-RAID mode (Enable
LVD SCSI) could cause data loss. Be sure your data is backed
up before you change to non-RAID mode.
If the value is not Enable HP NetRAID, use the +/- keys to change it to
Enable HP NetRAID. This change will take effect when the
HP NetServer restarts.
Exit Setup Utility
12. Press the F10 function key to save and exit.
13. In the Setup Confirmation dialog box, press Enter to answer "Yes" to the
question, "Save configuration changes and exit now?" The HP NetServer
will restart.