Integrated HP NetRAID Controller Config. Guide

Chapter 5 Configuration
59
Select Adapter to Configure
If you installed one or more HP NetRAID Series adapters, look in the Adapter
box to see if the integrated HP NetRAID controller is displayed. The integrated
HP NetRAID controller is always defined as Adapter 0. If not, select it from the
pull-down list.
Clear Configuration
You should clear the configuration to prepare it for the new configuration.
To clear the existing configuration:
1. Select the Configuration menu.
2. Choose Clear Configuration.
3. Click OK.
Check Rebuild Rate
During a rebuild, the contents of a complete physical drive are rewritten. Normal
operations can go on during a rebuild, but performance may be degraded. The
Rebuild Rate controls the rate at which a rebuild is performed. A high Rebuild
Rate (over 50%) speeds up the rebuild, but slows system performance. A low
Rebuild Rate (under 50%) slows the rebuild process, but speeds up system
performance. The default setting for the Rebuild Rate is 50%.
To check the Rebuild Rate from the HP NetRAID Assistant window:
1. Choose Rebuild Rate from the Adapter menu.
2. Reset the rate by dragging the slider with the mouse.
3. Click OK.
NOTE Clearing the configuration does not affect the rebuild rate.