Backup/Recovery Guide for HP AA Solutions

12/08/99 Hewlett-Packard Co. 7
IL Network Adapter
Enable – NetBEUI Protocol
Disable – TCP/IP Protocol
Disable – Wins Client (TCP/IP)
Enable – Marathon Datagram Services
Disable – Marathon Ethernet Provider
Enable – MTCEtx driver
Original Adapter (for default CE communication)
Disable - NetBEUI Protocol
Disable - TCP/IP Protocol
Disable - Wins Client (TCP/IP)
Enable - Marathon Datagram Services
Enable - Marathon Ethernet Provider
Disable - MTCEtx driver
Marathon MtcVnP Virtual Adapter
Enable - NetBEUI Protocol
Disable - TCP/IP Protocol
Disable - Wins Client (TCP/IP)
Disable - Marathon Datagram Services
Disable - Marathon Ethernet Provider
Disable - MTCEtx driver
New Network Adapter (for dedicated IOP communication to CE)
Disable - NetBEUI Protocol
Enable - TCP/IP Protocol
Enable - Wins Client (TCP/IP)
Enable - Marathon Datagram Services
Enable - Marathon Ethernet Provider
Disable - MTCEtx driver
Configure a unique IP address for each dedicated IOP network connection. Then, go to
the CE Network Properties, and change the bindings on both Marathon MtcVnR to the
following.
Marathon MtcVnR (for internal communication between IOP1 and CE)
Enable – NetBEUI Protocol
Disable – TCP/IP Protocol
Disable – Wins Client (TCP/IP)
Marathon MtcVnR (for internal communication between IOP2 and CE)
Enable – NetBEUI Protocol
Disable – TCP/IP Protocol
Disable – Wins Client (TCP/IP)