HP AA HP Netserver 4000 Reference Guide
HP NetServer AA
Hewlett-Packard Company
6-8
Enable - Marathon Datagram Services
Enable - Marathon Ethernet Provider
Disable - MTCEtx driver
2. Configure a unique IP address for each dedicated IOP network
connection.
3. Next, go to the CE Network Properties, and change the bindings
on both Marathon MtcVnR to the following.
• Marathon MtcVnR (for internal communication between IOP1
and CE)
Enable – NetBEUI Protocol
Disable – TCP/IP Protocol
Disable – Wins Client (TCP/IP)
• Marathon MtcVnR (for internal communication between IOP2
and CE)
Enable – NetBEUI Protocol
Disable – TCP/IP Protocol
Disable – Wins Client (TCP/IP)
• Marathon MTCETHR Virtual Adapter (public LAN on CE)
Enable – NetBEUI Protocol
Disable – TCP/IP Protocol
Disable – Wins Client (TCP/IP)
4. Reboot the HP AA system.
5. After reboot, check that you can ping IOP1 and IOP2 IP
addresses from the CE and from a third remote computer.
Network backup configuration
• Each pair of NICs assigned to CE, whether connected to the
public LAN or the backup LAN, must be properly configured
using Marathon Configuration Utility.
• Each IOP must have a separate backup NIC connected to the
backup LAN. The back-up network may also serve as the
management network. In this case some management tools, such
as TopTools, can access IOPs through the management network.