HP AA HP Netserver 4000 Reference Guide

Ch 5: System Upgrades
Network Server Division
5-7
This is the point where previous documentation comes in handy. By
comparing the previous 4 digit SCSI IDs with the IDs displayed in
the Registry it should be easy to pick out the new ID.
Record the new ID for future use. Make sure the other IOP has the
same 4 digit SCSI for the new device.
Modify the Marathon configuration on IOP1 and IOP2
Once the 4 digit SCSI ID has been acquired the Marathon
Configuration Utility can be run to add the new mirrored storage.
Launch the Configuration Utility.
Click the Disk Drives and click the Add button to add the new
storage. This is the point where the 4 digit SCSI ID must be entered.
Before entering this information make sure to verify it is the same on
both IOPs. Mismatches here could have catastrophic results on the
Array.
The figure below shows the Marathon Configuration with one disk
drive mirrored and redirected. The following figure shows the
display after the additional drive has been added to the list of
mirrored redirected devices.