HP NetServer AA 6200 Solution Release 3.0 Administrator's Guide
Chapter 5 Commands
130
IOPn.InputProvider Disable LED Flashing
This command disables the Scroll Lock LED from flashing the input device status. By default,
LED flashing is enabled, and the Scroll Lock LED flashes whenever the input devices are
logically connected to the local IOP.
Command IOPn.InputProvider Disable LED Flashing
Console Syntax MTCCONS IOPn.InputProvider Disable LED Flashing
Variables
n – the ID number of the IOP (1 or 2)
See Also IOPn.InputProvider Enable LED Flashing
IOPn.InputProvider Show LED Flashing
IOPn.InputProvider Enable Automatic Switchover
This command enables input devices to automatically switch over to the CEs whenever a CE
reboots. You can disable input devices from switching over by issuing an IOPn.InputProvider
Disable Automatic Switchover command.
By default, automatic switchover for input devices is enabled.
Command IOPn.InputProvider Enable Automatic Switchover
Console Syntax MTCCONS IOPn.InputProvider Enable Automatic Switchover
Variables
n – the ID number of the IOP (1 or 2)
See Also IOPn.InputProvider Disable Automatic Switchover
IOPn.InputProvider Set Input Devices CE
IOPn.InputProvider Set Input Devices IOP
IOPn.InputProvider Show Automatic Switchover