HP NetServer AA 6200 Solution Release 3.0 Administrator's Guide
Chapter 6 Configuration Utility
174
Committing When a Floppy Drive is Available
To commit configuration changes when a floppy drive is available on both IOPs:
Step Action Notes
1On the IOP where you made the changes:
a. Click Commit.
b. Insert a diskette in the floppy disk drive.
c. Click Save As, and save the
configuration onto the diskette
.
2 On the other IOP:
a. Insert the diskette (from Step 1) into the
floppy disk drive.
b. Using the Endurance Configuration
Utility:
- Click Open and open the configuration
file saved in Step 1.
- Click Commit.
3 If your server is operational:
a. Schedule an appropriate time to remove
your server from service and reboot the
IOPs
.
b. Issue an Endurance Manager Server
Shutdown command.
4 Reboot each IOP for the new configuration
to take effect.
The configuration information must be identical on