HP NetServer AA 6200 Solution Release 3.0 Administrator's Guide

185
Chapter 7 Tools and Utilities
Save Identity Setting Indicates whether the setting chosen above is changed or saved:
Modified
Saved
Note: Be sure you save settings before you exit the program.
MIC Connectivity Test Identifies the type of test to run:
Int-Loop Internal loopback. Uses the MICs internal loopback
capability to verify MIC operation in the local system.
Ext-Loop External loopback. Similar to the internal loopback
capability, but requires a fiber connection between the two ports.
Consequently, it also verifies the fiber segments and external
connectors.
Client Performs all available tests on both ports. At least one system
connected to port 1 or port 2 must be in Server mode. In this mode, all
ports and paths can be verified simultaneously, for example, if both
CEs are in Client mode, and both IOPs are in Server mode.
Server Places both ports in Server mode in order to make them
capable of responding to test requests from systems in client mode.
Disabled Indicates that all adapter connectivity tests are disabled.
Consequently, no tests will run.
Connectivity Test Duration Indicates the duration of the adapter connectivity test you perform:
Ten minutes
1 hour (the default)
3 hours
Forever a test that runs until stopped
Note: The durations of the adapter connectivity test listed above are a good
approximation. The actual durations may vary, depending on your
servers configuration.
Exit Exists the MIC BIOS Setup utility
Table 7-1 MIC BIOS Setup Window Parameters (Continued)
Parameter Description