HP NetServer AA 6200 Solution Release 3.0 Administrator's Guide
213
Chapter 9 Maintenance
Shutting Down a CE
To shut down a CE:
Shutting Down the CE Operating System
Before you shut down the CE operating system, consider the fact that this procedure removes
your server from service. Make sure that you schedule an appropriate time and that you have
completed any necessary backups before starting this procedure.
Note: You must complete the following procedure onsite. You cannot shut down the
CE operating system using remote Endurance Manager.
To shut down the CE operating system:
Step Action Notes
1 Make sure that the other CE is active. If the other CE is not active, shutting down the only
active CE removes the server from service.
2 From Endurance Manager issue the CEx
Disable command.
3 Power off the CE if desired. A disabled element will attempt to rejoin the server.
Step Action Notes
1 Make sure that the keyboard and mouse are
available at the CE.
If necessary, enter the hotkey sequence to switch
control to the CE operating system
2 Issue the command Windows NT Shutdown
without Restart.