HP NetServer AA 6200 Solution Release 3.0 Messages
125
Chapter 7 MtcEthP and MtcEtx Messages
IOPn.MtcEthP status: Invalid Registry parameter. Using default value.
Severity Warning
Description During initialization, MtcEthP reads optional parameters from the Registry. This message is
logged if a parameter is outside the acceptable range. The Event Log Data section contains the
invalid parameter value. MtcEthP will use the default value for the parameter.
Action • Run a Registry editor and note the values under
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\MtcEthP
\Parameters.
• Contact your service provider for assistance.
See Also The HP NetServer AA Manager command IOPn.EthernetProvider Show Parameter Values.
IOPn.MtcEthP status: Join response received, but device is not in the joining state.
Severity Error
Description An IOP join response was received, but joining is no longer in progress. A previous join may
have timed out, or there is an error in the Ethernet Provider joining protocol.
Action Contact your service provider for assistance.
IOPn.MtcEthP status: NdisRequest returned an error.
Severity Error
Description An NdisRequest to set or query the NIC failed. The Event Log Data section contains the
Windows NT error code. This message is logged during MtcEthP initialization or during IOP
state transitions. The NIC will be failed.
Action Reboot the IOP to clear the error condition on the NIC. You may want to power cycle the IOP
when you reboot it. Refer to Chapter 9 in HP NetServer AA Solution Administrator’s Guide for
information about how to reboot an IOP.