HP NetServer AA 6200 Solution Release 3.0 Messages

205
Chapter 13 MtcMon Messages
IOPn.MtcMon FRU: IOPx <-> CEy cross tuple fault.
Va r ia b le s x the ID of the IOP experiencing the fault
y the ID of the CE experiencing the fault
Because this is a cross-tuple fault, these variables are either: IOP1 and CE2, or IOP2 and CE1.
Severity Error
Description This message is generated when both the CE and IOP report a fatal condition. Usually, this is
the result of either:
A serious communication problem between the components
A secondary fault in the component that occurred in one component while a fault was
being handled for the other component
Action Run the MIC Connectivity Test in the MIC BIOS utility between the IOP and the CE to
ensure that the MIC adapters and the connections between them are functioning correctly.
If the condition persists with no indications of a faulty component, contact your service
provider for assistance.