HP NetServer AA 6200 Solution Release 3.0 Messages

227
Chapter 13 MtcMon Messages
IOPn.MtcMon status: An error occurred activating IOPx on the active CEs.
Va r ia b le s x the ID of the IOP that had an error during activation
Severity Error
Description An error occurred while attempting to join an IOP into an Endurance server that has an active
CE. The active IOP was attempting to activate the joining IOP with the CE, and a failure
occurred. A problem has occurred with the ESI between the active CE and the joining IOP.
Related Messages
IOPn.MtcMon status: The join process has failed for IOPx.
Hardware/Software This condition usually indicates a hardware failure in the active CE, the joining IOP, or the ESI
between them.
Action Verify that the ESI is valid and properly connected.
Reboot the joining IOP and allow it to rejoin the Endurance server configuration. Refer to
Chapter 9 in HP NetServer AA Solution Administrators Guide for information about how
to reboot an IOP.
IOPn.MtcMon status: An error occurred loading the thresholding database on the joining IOP. IOP initialization and
joining will be retried.
Severity Error
Description This message is generated during the IOP joining process that occurs when an IOP starts up.
An unexpected error occurred on the IOP that was joining the Endurance server configuration
when it was loading the thresholding database from the remote IOP.
Related Messages
IOPn.MtcMon status: IOPx is faulted and requires repair.
IOPn.MtcMon status: The join process has failed for IOPx.
Hardware/Software This message indicates a software error.
Action This message is thresholded when it occurs. If the threshold is not exceeded, the IOP joining
process is retried and is successful in most cases. If the threshold is exceeded, the joining IOP
is marked faulted. This failure occurs as a result of a corruption in the Windows NT Registry
that can be fixed by re-installing Endurance server software.