HP NetServer AA 6200 Solution Release 3.0 Messages

Chapter 13 MtcMon Messages
240
IOPn.MtcMon status: CEx could not be booted because the SCSI boot driver has not registered with the Monitor on
IOPy.
Va r ia b le s x the ID of the CE that could not be booted
y the ID of the IOP driving the boot process
Severity Error
Description A CE issued a boot request to an IOP that does not have the Endurance SCSI Provider loaded
and active. If both IOPs are active, this message should occur on both simultaneously.
Hardware/Software This message is usually due to a software configuration error that results in the Endurance
SCSI Provider not being loaded. It can also be due to a failure of the SCSI Provider.
Action During Endurance server configuration, at least one mirrored SCSI disk must be
configured. If this is not the case, reconfigure the IOP (or IOPs) and reboot. Refer to
Chapter 9 in HP NetServer AA Solution Administrators Guide for information about how
to reboot an IOP.
Examine the event log to determine if the Endurance SCSI Provider loaded properly, and
if appropriate, repair any problems indicated. The CE boots when the IOP reboots and has
a properly loaded SCSI Provider.
IOPn.MtcMon status: CEx could not be removed or disabled because CE synchronization is currently in progress.
Va r ia b le s x the ID of the CE that could not be removed or disabled
Severity Warning
Description This message is generated when the CE is active and you issued a CE Remove or CE Disable
command while CE synchronization was in progress. These operations cannot be performed
during CE synchronization.
Hardware/Software This message is generated as a result of a software condition.
Action The CE Remove or CE Disable command was not performed. Reissue the command when the
CE synchronization process has completed.