HP NetServer AA 6200 Solution Release 3.0 Messages
Chapter 13 MtcMon Messages
252
IOPn.MtcMon status: ESIx is faulted and requires repair.
Va r ia b le s x – the ID of the Endurance System Interconnect (ESI) that is faulted
Severity Error
Description The ESI specified in the message has experienced one or more failures that prevent it from
being used in the Endurance server configuration. The ESI remains in the faulted state until
you resolve the situation.
Often an IOP or CE is also removed when this message occurs.
Related Messages
IOPn.MtcMon status: IOPx has been removed from service.
IOPn.MtcMon status: CEx has been removed from service.
Hardware/Software This message is usually a result of a hardware failure.
Action • Examine the event log for additional details about the reason for the failure.
• Repair and/or replace any faulty hardware as necessary.
• Once you resolve the condition, issue an ESI Enable Operation command. The Endurance
server attempts to reconfigure as required.
IOPn.MtcMon status: IL12 has been enabled by operator request.
Severity Informational
Description IL12 was enabled using the IL12 Enable command. IL12 was previously faulted and is now
available.
Related Messages
IOPn.MtcMon status: IL12 is FAULTED and requires repair.
Hardware/Software This message is generated as a result of issuing a software command.
Action No action is required.