HP NetServer AA 6200 Solution Release 3.0 Messages
Chapter 13 MtcMon Messages
274
IOPn.MtcMon status: The CE CPU ID 0xx power-on settings do not match.
CE1 CPU power-on settings = 0xy.
CE2 CPU power-on settings = 0xz.
Va r ia b le s x – the ID of incompatible CPUs
y – the CPUx power-on settings in CE1
z – the CPUx power-on settings in CE2
Severity Error
Description The CPU power-on settings for CPUx in CEs 1 and 2 are not identical. The CEs cannot be
synchronized unless the power-on settings of the same ID CPUs in each CE match exactly.
Hardware/Software The message is generated as a result of a hardware configuration error in the CEs.
Action To resolve this condition, do one of the following:
• Power down one of the CEs and replace CPUx with a CPU with identical power-on
settings to CPUx in the active CE.
• Power down both CEs and replace CPUx in both CEs with CPUs with identical power-on
settings.
IOPn.MtcMon status: The CE CPU ID 0xx speeds do not match.
CE1 CPU speed = y MHz
CE2 CPU speed = z MHz
Va r ia b le s x – the ID of incompatible CPUs
y – the CPUx speed in CE1
z – the CPUx speed in CE2
Severity Error
Description The CPU speeds for CPUx in CEs 1 and 2 are not identical. The CEs cannot be synchronized
unless the speed of the same ID CPUs in each CE match exactly.
Hardware/Software This message is generated as a result of a hardware configuration error in the CEs.
Action To resolve this condition, do one of the following:
• Power down one of the CEs and replace CPUx with a CPU with identical speed to CPUx
in the active CE.
• Power down both CEs and replace CPUx in both CEs with CPUs with identical speeds.