HP NetServer AA 6200 Solution Release 3.0 Messages
313
Chapter 14 MtcScsiP and MtcScsiR Messages
IOPn.MtcScsiP status: DEVICEn location does not contain the expected device type.
Va r ia b le s n – the device number; for example, DISKn, CDROMn, TAPEn
Error
Description A device located at a configured SCSI address was not the expected device type. For example,
the software may have been configured to expect a disk drive at a particular SCSI address, but
instead, it encountered a CDROM drive.
Action • Verify the HP NetServer AA configuration file is set up properly.
• If so, check whether the installation of any new SCSI hardware devices or adapters may
have caused a change in the physical SCSI address of a device.
IOPn.MtcScsiP status: DEVICEn powered up successfully.
Va r ia b le s n – the device number; for example, DISKn, CDROMn, TAPEn
Informational
Description A configured device has been found and appears to have powered up without problems.
Action No action is required.
IOPn.MtcScsiP status: DEVICEn was not found, and it will be marked offline.
Va r ia b le s n– the device number; for example, DISKn, CDROMn, TAPEn
Severity Error
Description No device at a configured SCSI address was found. This may be because the device is powered
off, not present, not connected to the SCSI bus, has failed, or is misconfigured, for example.
Action • Verify the HP NetServer AA configuration file is set up properly.
• If so, power off the IOP and verify the device is powered on, connected to the SCSI bus,
and has not failed.
IOPn.MtcScsiP status: Disk could not be enabled.
Severity Error
Description The administrator was unable to enable the specified disk using the HP NetServer AA
Manager.
Action No action is required.