HP NetServer AA 6200 Solution Release 3.0 Messages
53
Chapter 2 MIC BIOS Messages
MIC identity unknown
Severity Informational
Description The MIC element identity (CE1, CE2, IOP1, IOP2) has not been specified in non-volatile
memory (or has been reset to the “Unknown” setting). The MIC BIOS automatically places the
system in the setup utility so an identity can be selected.
Action • Select the appropriate element identity.
• Save the setting in non-volatile memory.
• Upon exiting the setup utility, reboot the appropriate element to reinitialize the firmware
to the new setting.
MIC initialization complete
Description The MIC initialization performed at system POST (Power-On Self Test) is complete. If this is
an IOP, this is the last message displayed by the MIC BIOS. On CEs, control returns to the
System BIOS to complete initialization. The MIC later regains control to manage the boot or
synchronization process.
Action No action is required.
MIC internal error: module linen context context data
Va r ia b le s n – the line number
Severity Error
Description An unexpected hardware or firmware error was detected in the specified module at the
specified line. The context data provides additional information about the error.
This error should not occur during normal operation.
Action Contact your service provider for assistance.