HP NetServer AA 6200 Solution Release 3.0 Messages

Chapter 2 MIC BIOS Messages
54
MIC internal warning: module linen context context data
Va r ia b le s n the line number
Severity Error
Description An unexpected hardware or firmware condition was detected in the specified module at the
specified line. The context data provides additional information about the warning.
This warning should not occur during normal operation.
Action Contact your service provider for assistance.
MIC not found
Severity Error
Description The MIC adapter was not found. This error is most likely due to a hardware malfunction, PCI
system incompatibility, or a mismatch between the firmware version and the MIC
.
Action Update the firmware on the MIC.
Examine the system BIOS settings to ensure that your PCI slots are properly configured.
To determine if there is an incompatibility between the MIC and the PCI system in which
it is currently installed, try the MIC on a different system.
If the error persists, replace the MIC.
MIC system error detected by CEx involving IOPy: error identifier
MIC error context: context data
Va r ia b le s x the ID of the CE that detected the error
y the ID of the IOP experiencing the error
VariablesSeverity Error
Description A hardware error was detected by the specified CE indicating the specified IOP or path to that
element is in error. The error context always follows this message and contains data unique to
the error.
This error should not occur during normal operation.
Action Contact your service provider for assistance.