HP NetServer AA 6200 Solution Release 3.0 Messages
55
Chapter 2 MIC BIOS Messages
Negotiating HP NetServer AA startup with IOPx. . .
Va r ia b le s x – the ID of the IOP with which communication has been established and the startup process
is beginning
Severity Informational
Description Communication has been established with the specified IOP, and the startup process is
beginning.
Action No action is required.
No MIC identity found: A MIC identity must be assigned and saved. Press <Enter> to continue.
Severity Informational
Description The MIC element identity (CE1, CE2, IOP1, IOP2) has not been specified in non-volatile
memory (or has been reset to the “Unknown” setting).
Action • Select the appropriate element identity.
• Save the setting in non-volatile memory.
• Upon exiting the setup utility, reboot the appropriate element to reinitialize the firmware
to the new setting.
Performing client tests. Please ensure remote port(s) are in server mode.
Severity Informational
Description For a client test, the ports to be included in the test must be physically connected and listening
in server mode.
Action When the remote port(s) are in server mode, press any key to continue the test.
Performing external loopback tests. Please ensure MIC ports are connected.
Severity Informational
Description For an external loopback test, the MIC ports must be connected with a fiber cable.
Action When the ports are connected, press any key to continue the test.