HP NetServer AA 6200 Solution Release 3.0 Messages
57
Chapter 2 MIC BIOS Messages
Response timeout: message description
Severity Error
Description A response was not received in the time allotted. This can occur if the CE loses communication
with the IOP providing boot or synchronization services, or if a hardware fault occurs.
Action • Run the MIC BIOS client-server diagnostics between the CE and the IOP providing
startup services to verify that the hardware is functioning properly.
• Consult the startup IOP’s event log for possible additional information.
• If the error persists, contact your service provider for assistance.
Test test type on port port completed successfully.
Severity Informational
Description The specified test completed without errors.
Action No action is required.
Test test type on port port failed.
Severity Informational
Description The specified test completed with an error. Additional error detail is provided in the messages
displayed just prior to this.
Action No action is required.
Test test type started on port port.
Severity Informational
Description The specified test has been started on the specified port. For client-server tests, this indicates
communication has been established with the remote system on the specified port.
Action No action is required.