74
MtcCEX: Could not transition any IOP MIC port to ACTIVE.
Severity Error
Description This message displays in a Windows NT blue screen on a monitor attached directly to a CE
during CE operating system boot if the HP NetServer AA CE Transport cannot activate a MIC
connection to any IOP. The CE operating system boot terminates.
Related Messages
MtcCEX: Could not transition IOPx MIC port to ACTIVE.
Hardware/Software This message is most likely the result of a failure of the CE MIC adapter.
Action If CE boot does not succeed after retrying, replace the CE MIC.
If the problem persists, contact your service provider for assistance.
MtcCEX: Could not transition IOPx MIC port to ACTIVE.
Va r ia b le s x ID of the IOP associated with the MIC adapter port that failed.
Severity Error
Description This message displays in a Windows NT blue screen on a monitor attached directly to a CE
during CE operating system boot when the HP NetServer AA CE Transport cannot activate a
MIC adapter port as requested by the IOP during the boot process. The CE transport attempts
to continue the boot process.
Related Messages
MtcCEX: Could not transition any IOP MIC port to ACTIVE.
Hardware/Software This message is most likely the result of a failure of the CE MIC adapter or an IOP MIC
adapter.
Action If CE boot does not succeed immediately or after retrying, first replace the CE MIC
adapter, and then replace the IOP MIC adapter.
If the problem persists, contact your service provider for assistance.