HP NetServer AA 6200 Solution Release 3.0 Messages
Chapter 4 MtcCEX Messages
74
MtcCEX: Could not transition any IOP MIC port to ACTIVE.
Severity Error
Description This message displays in a Windows NT blue screen on a monitor attached directly to a CE
during CE operating system boot if the HP NetServer AA CE Transport cannot activate a MIC
connection to any IOP. The CE operating system boot terminates.
Related Messages
MtcCEX: Could not transition IOPx MIC port to ACTIVE.
Hardware/Software This message is most likely the result of a failure of the CE MIC adapter.
Action • If CE boot does not succeed after retrying, replace the CE MIC.
• If the problem persists, contact your service provider for assistance.
MtcCEX: Could not transition IOPx MIC port to ACTIVE.
Va r ia b le s x – ID of the IOP associated with the MIC adapter port that failed.
Severity Error
Description This message displays in a Windows NT blue screen on a monitor attached directly to a CE
during CE operating system boot when the HP NetServer AA CE Transport cannot activate a
MIC adapter port as requested by the IOP during the boot process. The CE transport attempts
to continue the boot process.
Related Messages
MtcCEX: Could not transition any IOP MIC port to ACTIVE.
Hardware/Software This message is most likely the result of a failure of the CE MIC adapter or an IOP MIC
adapter.
Action • If CE boot does not succeed immediately or after retrying, first replace the CE MIC
adapter, and then replace the IOP MIC adapter.
• If the problem persists, contact your service provider for assistance.