HP NetServer AA 6200 Solution Release Notes (Release 3.0 Service Pack 1)
7
HP NetServer AA Solution Release Notes
You can run the Endurance Performance Monitor plug-in on either the CE or an IOP in an HP
NetServer AA Solution server running Release 3.0 Service Pack 1. The standard Windows NT
Performance Monitor must already be installed on the server before running the Endurance
Performance Monitor plug-in.
The HP NetServer AA Solution software installation process automatically installs the
Endurance Performance Monitor. During HP NetServer AA Solution installation, the following
files are installed in the folder
\Program Files\Marathon Endurance:
• MTCPERF.DLL
• MTCIPERF.EXE
• MTCUPERF.EXE
Operating the Endurance Performance Monitor
You can use the Endurance Performance Monitor counter with all the standard capabilities of
the Windows NT Performance Monitor, such as charting and logging.
To operate the Endurance Performance Monitor plug-in to track performance on both CE
Processors:
Redirected Ethernet Card Replacement without Server Reboot
Release 3.0 Service Pack 1 introduces the capability of replacing redirected Ethernet cards
without having to reboot the entire server.
Step Action Notes
1 Launch the Windows NT Performance
Monitor.
2
Select the Endurance
Processor object.
3 Select the % Processor 1 Time counter. The % Processor 1 Time counter is updated once
every .75 seconds. For accurate readings, in the
Chart Options dialog box, do not set the Update
Time Interval value to less than 1 second.
4 Select the standard Processor object, %
Processor Time counter, Instance 0.
Use this selection to monitor the CE Processor 0.