HP Netserver AA Solution Administrator's Guide v4.0 SP1

5-60 HP Netserver AA Solution Administrator’s Guide
Results
Table 5-24 IOP LinkDriver Show Parameter Values
See Also IOPn.LinkDriver Show Port Counters
Value Meaning
Heartbeat Interval Interval in seconds at which heartbeat PDUs are transmitted
Circuit Timeout Number of seconds in which a heartbeat or other PDU must
be received
Maximum Transmit Retries Maximum number of times a Data PDU will be retransmitted
Transmit Timeout Number of seconds in which a Data PDU must be
acknowledged (ACKed)
Send Window Size The maximum send window size for Data PDUs. This is the
number of Data PDUs that can be sent before an ACK must
be received.
NDIS Packet Pool Size for Send Size of NDIS_PACKET pools for sends
NDIS Packet Pool Size for Receive Size of NDIS_PACKET pools for receives
NDIS Buffer Pool Size Size of NDIS_BUFFER pool for sends and receives