HP Netserver AA Solution Administrator's Guide v4.0 SP1

Endurance Server Maintenance 9-15
6 Make sure that any components
affected by this procedure are active or
online. Reenable any faulted or
disabled components (page 9-31).
Use Endurance Manager for this step.
7 Confirm that the new Ethernet cable
operates properly:
Establish a network connection to
validate that the connection is
operating properly.
Issue an Endurance Manager
Disable IOPy.Ethernet command.
Issue an Endurance Manager
Enable IOPy.Ethernet command
for the Ethernet connection disabled
in the previous step.
Using the Endurance Manager main
window, confirm that the Ethernet
connection that uses the
replacement cable is active and
primary.
Verify continued client connectivity.
Use Endurance Manager for these steps.
For example, use Windows Explorer to connect
to a network node. Copy some files to and from
the server during the following steps.
This disables the Ethernet connection that
maintained network connectivity while you
completed the previous steps.
It appears bright green.
If the Ethernet connection supported by the
replacement cable remains active and primary,
the cable that you replaced is fully operational.
The file copies continue and complete without
errors, and the IOP connection (using the
replacement cable) remains online for one
minute or more.
Step Action Notes