HP Netserver AA Solution Administrator's Guide v4.0 SP1

9-22 HP Netserver AA Solution Administrator’s Guide
Replacing a CE
Caution: Before proceeding, make sure you are properly grounded using,
for instance, a wrist strap with an attached alligator clip that is
connected to an appropriate ground
To replace a CE:
Updating MIC BIOS, FPGA, and Microcode
The MIC BIOS, FPGA, and microcode on the CEs and IOPs must be identical on all CEs and
IOPs for the Endurance server to function properly. Use the MTCFLASH Utility, described in
Chapter 7, to upgrade the microcode revision levels.
Step Action Notes
1 Shut down the CE as described on
page 9-8.
2 Power off the CE.
3 Detach and label the following cables
from the CE:
The power cord.
The MIC fiber cables by squeezing
the connectors to unclip them and
detaching them.
The video cable.
4 If the CE is rackmounted, remove it
from the rack.
5 Prepare the new CE for installation, as
described in Chapter 1 of the HP
Netserver AA Solution Installation
Guide.
Follow the procedure given in Chapter 2 of the
Endurance Installation Guide.
6 If required, fasten the rackmount
brackets and install it in the rack.
7 Power up the CE.