hp lp 1000r and ds2100 config guide - for Microsoft Windows 2000 A.S. Clusters PDF, 252K, 11/15/2001

LP1KR2K2M21
11/15/01 3
Shared Storage Configuration
Parameter Specification
Configuration options Termination disabled by physical jumper setting -- Cover J3 pins 2-3.
See jumper diagram on page 5.
Cluster mode on
Cache write policy to Write thru
Enclosure
Disk drives Any HP drive supported by storage enclosure. Any combination of HP disk
models is allowed in an array, on a SCSI channel, or in a cluster.
Number of cabinets One or two per cluster
Model HP Surestore DS2100 A5676A
Disk SCSI IDs SCSI ID switch B or C
SCSI ID
Switch Settings
When daisy-chaining two DS2100 enclosures, each must have a different switch
setting. Set one DS2100 to switch B, and the other to switch C. In single DS2100
clusters, set the switch to either B or C.
B 8,10,12,14
C 9,11,13,15
Cables
SCSI C7541A (Quantity = two, required)
2 Meter in-line terminated cable (to connect NetRAID-2M to DS2100)
C2978B (Quantity = one needed only when configuring two DS2100s in the
cluster)
- 0.5 meter LVD cable
See SCSI cabling diagrams starting on page 6.
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power cabling
diagram on page 8.
Microsoft
and HP Certified Server Configuration
Parameter Specification
Server
I/O card slot PCI slot 1, NetRAID-2M shared storage controller
Network interfaces Embedded NICs for both intra-cluster (heartbeat) and client LANs
Boot device Embedded SCSI
Intra-Cluster (Heartbeat) LAN Configuration
Parameter Specification
Network
Connection
HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication. It may
not be used for client communication.
NIC
Quantity One