hp lp 1000r and ds2100 config guide - for Microsoft Windows 2000 A.S. Clusters PDF, 252K, 11/15/2001

LP1KR2K2M21
11/15/01 4
Intra-Cluster (Heartbeat) LAN Configuration
Parameter Specification
Model Embedded NIC LAN A
Driver Hptxnt5.sys, version 4.02.27, or later
(driver obtained from Navigator CD-ROM L.20.00, or later)
Client LAN Configuration
Parameter Specification
Network
Connection Any LAN
NIC
Quantity One
Model Embedded NIC LAN B
Driver Hptxnt5.sys, version 4.02.27, or later
(driver obtained from Navigator CD-ROM L.20.00, or later)
Special Notes and Warnings
Disk Drive LEDs
There is no hardware support in the DS2100 for disk drive failure detection or
indication by disk drive LEDs (Light Emitting Diodes). A failed drive cannot be
identified by an LED signal. Only disk spin-up and data access activity is indicated
by a green flashing light on a disk drive LED.
Disconnected SCSI cables
SCSI cables must not be disconnected while both server nodes are up. Cluster
failover may not occur upon a SCSI cable being disconnected at a live node. Only
disconnect a SCSI cable from a server that is powered off. Also, do not disconnect
a SCSI cable interconnecting two DS2100 enclosures on a live cluster because
cluster failures may result from the SCSI bus not being terminated.
NetRAID-2M channels
When connecting the NetRAID-2M SCSI cables to the DS2100, only use
NetRAID-2M channel 0. Cluster failure could result and there is a potential for
data loss from connections to channel 1 and so channel 1 connections are not
supported.