hp lp 1000r netraid-2m config guide - for Microsoft Windows 2000 A.S. Clusters PDF, 86K, 11/7/2001

LP1000R2K2M
11/7/01 2
Server Configuration
Parameter Specification
I/O slot PCI slot 1
Default boot order IDE CD-ROM, FDD, embedded SCSI, PCI slot 1
Local Storage
Controller Embedded SCSI
Driver Sym_u3.sys, version 5.07.00, or later
(driver obtained from Navigator CD-ROM L.20.00, or later)
Physical drive location Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives Must be HP
SCSI bus Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs Any
System software
Navigator CD-ROM Version M.04.00, or later
Operating system
Service pack
Microsoft Windows
2000 Advanced Server
Latest service pack version
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power cabling
diagram on page 6.
Shared Storage Configuration
Parameter Specification
Controller
Model HP NetRAID-2M Controller, Model P3411A, or P3475A
Number of controllers One
BIOS Disabled
Firmware Version H.01.08
(firmware obtained from Navigator CD-ROM, version M.04.00, or later)
Driver Mraid2k.sys, version 5.20
(driver obtained from Navigator CD-ROM, version L.20.00, or later)
NetRAID Assistant Version B.01.04, or later
(software obtained from Navigator CD-ROM, version L.20.00, or later)
SCSI ID 6, 7
Channels 0, 1
RAID levels 1, 5, 10, 50
Logical disks One per RAID array
Eight, maximum, per cluster
Configuration options Cluster mode on
Cache write policy to Write thru
Enclosure
Disk drives Any HP drive supported by storage enclosure. Any combination of HP disk
models is allowed in an array, on a SCSI channel, or in a cluster.
Number of cabinets One or two per NetRAID-2M controller