hp lp 1000r netraid-2m config guide - for Microsoft Windows 2000 A.S. Clusters PDF, 86K, 11/7/2001

LP1000R2K2M
11/7/01 3
Shared Storage Configuration
Parameter Specification
Model Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID 5 (fixed)
Disk SCSI IDs 03, 815 (fixed)
Cables
SCSI Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See SCSI cabling diagram on page 5.
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power cabling
diagram on page 6.
Microsoft
and HP Certified Server Configuration
Parameter Specification
Server
I/O card slot PCI slot 1, NetRAID-2M shared storage controller
Network interfaces Embedded NICs for both intra-cluster (heartbeat) and client LANs
Boot device Embedded SCSI
Intra-Cluster (Heartbeat) LAN Configuration
Parameter Specification
Network
Connection HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication. It may
not be used for client communication.
NIC
Quantity One
Model Embedded NIC- LAN A
Driver Hptxnt5.sys, version 4.02.27, or later
(driver obtained from Navigator CD-ROM L.20.00, or later)