HP Netserver DiagTools v1.0x User Guide

Chapter 5 Error Message Reference
30
Code Description Recommended Action
3. Be sure the processor board (if any) is seated.
4. Make sure the CPU chip is seated.
5. Make sure the memory elements (DIMMs) are properly seated.
6. Check system fans. If overheating occurs, chip may shut down.
7. If the system ran with temperature high, let it cool for 30 minutes, then restart.
8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
002Bh Integer load or store
error.
1. Take ESD precautions and make sure the system board is seated.
2. Check the seating of the voltage regulator module (VRM) if present.
3. Be sure the processor board (if any) is seated.
4. Make sure the CPU chip is seated.
5. Make sure the memory elements (DIMMs) are properly seated.
6. Check system fans. If overheating occurs, chip may shut down.
7. If the system ran with temperature high, let it cool for 30 minutes, then restart.
8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
002Ch NDP Tag word read
or write error.
1. Take ESD precautions and make sure the system board is seated.
2. Check the seating of the voltage regulator module (VRM) if present.
3. Be sure the processor board (if any) is seated.
4. Make sure the CPU chip is seated.
5. Make sure the memory elements (DIMMs) are properly seated.
6. Check system fans. If overheating occurs, chip may shut down.
7. If the system ran with temperature high, let it cool for 30 minutes, then restart.
8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
002Dh NDP stack pop
error.
1. Take ESD precautions and make sure the system board is seated.
2. Check the seating of the voltage regulator module (VRM) if present.
3. Be sure the processor board (if any) is seated.
4. Make sure the CPU chip is seated.
5. Make sure the memory elements (DIMMs) are properly seated.
6. Check system fans. If overheating occurs, chip may shut down.
7. If the system ran with temperature high, let it cool for 30 minutes, then restart.
8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
002Eh -
002Fh
NDP Tag word read
or write error.
1. Take ESD precautions and make sure the system board is seated.
2. Check the seating of the voltage regulator module (VRM) if present.
3. Be sure the processor board (if any) is seated.
4. Make sure the CPU chip is seated.
5. Make sure the memory elements (DIMMs) are properly seated.
6. Check system fans. If overheating occurs, chip may shut down.
7. If the system ran with temperature high, let it cool for 30 minutes, then restart.
8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.