HP Netserver DiagTools v1.0x User Guide

Chapter 5 Error Message Reference
49
FDD (Flexible Disk Drive or Floppy) Tests
Flexible Disk Drives are tested for rotational speed, elevator, and seek channel.
Code Description Recommended Action
0301h Undefined or
invalid command.
1. Try a different diskette.
2. Check the cable between the floppy drive and the system board.
3. Change the floppy drive.
4. Change the system board.
0302h DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
0303h DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
0304h DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
0305h Reset failed.
DiagTools issued a
reset command and
it was not accepted
or confirmed by the
floppy disk
controller.
1. Try a different diskette.
2. Check the cable between the floppy drive and the system board.
3. Change the floppy drive.
4. Change the system board.
0307h Drive parameter
activity failed.
1. Try a different diskette.
2. Check the cable between the floppy and the system board.
3. Change the floppy drive.
4. Change the system board.
0308h DMA Overrun
error.
1. Try a different diskette.
2. Check the cable between the floppy and the system board.
3. Change the floppy drive.
4. Change the system board.
0309h Attempt to DMA at
64 KB boundary.
1. Try a different diskette.
2. Check the cable between the floppy and the system board.
3. Change the floppy drive.
4. Change the system board.
030Ah DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
0310h Floppy CRC or
ECC data error.
1. Try a different diskette.
2. Check the cable between the floppy drive and the system board.
3. Change the floppy drive.
4. Change the system board.
0311h DiagTools Error Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
0321h The circuit that
detects changed
diskettes is not
working.
1. Try a different diskette.
2. Check the cable between the floppy drive and the system board.
3. Change the floppy drive.
4. Change the system board.