hp netserver lc 2000 netraid-3si configuration - for Microsoft NT 4.0 Clusters PDF, 272K, 1/26/2002

lc2000nt3Si
01/26/02
2
Server Configuration
Parameter Specification
Number of power
supplies
One standard, two required for redundancy
I/O slots Added cards may be installed in any appropriate slot, considering the server
default boot order provided below:
Default boot order IDE CD-ROM, FDD, embedded SCSI A, embedded SCSI B, PCI slot 1, PCI
slot 2, PCI slot 3, PCI slot 4, PCI slot 5, PCI slot 6
Local Storage
Controller Embedded SCSI, NetRAID-1Si, or NetRAID-3Si.
Driver For embedded SCSI, sym_hi.sys, version 4.12, or later
For NetRAID-1Si or NetRAID-3Si, mraidnt.sys, version 2.24
(all drivers obtained from Navigator CD-ROM, version L.18.04.5, or later)
Physical drive location Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives Must be HP (hot swapped or fixed)
SCSI bus Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI Ids Any
System Software
Navigator CD-ROM Version L.18.00, or later
Operating system
Microsoft Windows NT
Server 4.0, Enterprise Edition
Service pack SP6a
Power Distribution
Layout Redundant power distribution units (PDUs) are recommended. See power-
cabling diagram on page 6.
Shared Storage Configuration
Parameter Specification
Controller
Model HP NetRAID-3Si Controller, Model D5955A
Number of controllers One
BIOS B.02.02
Firmware Version W.01.30 (firmware obtained from Navigator CD-ROM, version
L.18.04.5, or later)
Driver Mraidnt.sys, version 2.24
NetRAID Assistant Version A.01.15, or later
(software obtained from Navigator CD-ROM, version L.18.04.5, or later
SCSI IDs 6, 7
Channels 0, 1, 2
RAID levels 1, 5, 10, 50
Logical disks One per RAID array
Eight, maximum, per cluster