hp netserver lc 2000 netraid-3si configuration - for Microsoft NT 4.0 Clusters PDF, 272K, 1/26/2002

lc2000nt3Si
01/26/02
3
Shared Storage Configuration
Parameter Specification
Configuration options Cluster mode on
Cache write-policy to Write-thru
Set any other option as desired
Enclosure
Disk drives Any HP drive supported by storage enclosure. Any combination of HP disk
models is allowed in an array, on a SCSI channel, or in a cluster.
Number of cabinets One, two, or three
Model HP Rack Storage/12 D5989B, containing two D6025B SCSI controller cards, or
HP Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI IDs 5 (fixed)
Disk SCSI IDs 0 3, 8 15 (fixed)
Cables
SCSI Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See SCSI cabling diagram on page 5.
Power Distribution
Layout Redundant power distribution units (PDUs) are recommended. See power-
cabling diagram on page 6.
Microsoft
®
and HP Certified Server Configuration
Parameter Specification
Server
I/O controller PCI slot 1, NetRAID-1Si local storage controller
PCI slot 5, NetRAID-3Si shared storage
Network interfaces PCI slot 3, client LAN, model D5013B NIC
Boot device Embedded SCSI in tests up to 1000 MHz
NetRAID-1Si in 1000 MHz certification
Intra-Cluster (Heartbeat) LAN Configuration
Parameter Specification
Network
Connection HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication. It
may not be used for client communication.