HP Netserver LH 3000 NetRAID-4M Config Guide for Windows 2000 Advanced Server Clusters

2
Power source Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDUs) are strongly recommended.
System software:
Navigator version L.20.00 or later
Operating System
Service Pack
Microsoft Windows
2000 Advanced Server
SP1
SPU
Model HP NetServer LH3000
Clock speed 1000 MHz
No. of CPUs 2
BIOS version 4.06.31 PT or later
CPU cache Any size
RAM 256 MB minimum. Must be HP.
No. of power supplies 2 standard, 3 required for redundancy, 4 for redundant power cords
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind the
servers default boot order as listed below:
Default Boot Order IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI-8, PCI-7,
PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
Microsoft
and HP
Certified
Configuration
P5 – Client LAN – D5013B
P7– Shared Storage – NetRAID-4M
Booted from Embedded DAC
Storage
Local
Controller May use embedded SCSI, embedded DAC, NetRAID-1Si, NetRAID-3Si,
NetRAID-1M or NetRAID-2M.
Driver For embedded SCSI, use sym_hi.sys 4.12 or later.
For Embedded DAC or NetRAID-xSi, use mraid35x.sys version 2.66.
For NetRAID-1M/2M, use mraid2k.sys, version 5.20 or later.
All are from Navigator L.20.00 or later.
Physical drive location SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12)
Disk drives Must be HP
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed
SCSI Ids Any
Shared
Controller
Model HP NetRAID-4M Adapter D9161A or D9351A
No. of controllers 2
BIOS
Disabled
Firmware 4584
Driver Hpn.sys version 2.4.0.4581