HP Netserver LXr Pro8 Surestore E Config Guide for Windows NT4.0 Clusters

3
Shared Storage
Host Bus Adapter
Model HP A5252B Wide Differential SCSI Adapter.
No. of HBA 1-3 per NetServer.
Driver Adaptec AHA-294X/AHA-394X/AIC-78XX SCSI Controller”
driver in NT 4.0 SP3 or later
SPU I/O slot P5 (1
st
HBA), P6 (2
nd
HBA), P7 (3
rd
HBA)
SCSI ID 7
Disk Array Controller
Model HP A3706A 96MB Controller with SureStore E 12H
No. of controllers 2 per SureStore E 12H
Firmware HP32 or later.
RAID level (internal) 1/0 and 5
Logical disks Logical units within each array must be numbered from 0-7.
Hot spare Active Hot Spare.
SCSI ID 0-6 or 8-15
Disk Array Storage
Model HP A3700AB SureStore E 12H Disk Array (Option ASJ)
No. of cabinets 1-6 with a maximum of 2 SureStore E 12Hs per SCSI bus
Disk modules: HP A3702A 4.2 GB Disk Module;
HP A3703A 9.1 GB Disk Module;
HP A3710A 18.2 GB Disk Module.
Power supply 3
AutoRAID Manager (ARM) 1.01 or later.
Cabling HP C2981A 0.5 meter Ultra-flexible SCSI Cable;
HP C2911A 0.9 meter 68-pin HD Male to 68-pin HD Male Cable;
HP C2924A 2.5 meter 68-pin HD Male to 68-pin HD Male Cable;
HP C2925A 10 meter 68-pin HD Male to 68-pin HD Male Cable.
Maximum 25 meters per SCSI bus.
Terminator HP C2905A Wide Differential SCSI Terminator.