Introduction
This document defines the supported HP NetServer LH II and A3700AB HP SureStore E 12H Disk Array
configurations for Microsoft Cluster Server. These configurations minimize single points of failure, provide
maximum availability, and have been certified by Hewlett-Packard and Microsoft. This guide is prescriptive; it
describes the configurations supported by HP. Any configuration not expressly allowed by this guide will not be
supported by HP.
What’s Defined
Cluster
SPUs
LANs
Local Storage
Shared Storage
Shared Storage Cabling
Cluster
Type of SPUs HP NetServer LH II
Each node must be the same model SPU, but may have different size
main memory and clock speeds as long as both SPU meets the minimum
requirements as stated in the SPU section.
Number of nodes 2
Shared Storage See Shared Storage below.
LANs:
Client See Client LAN below.
Intra-cluster See Intra-cluster LAN below.
Power source Direct from power mains, power conditioner or uninterruptable power
supply (UPS) using any power conditioner or UPS.
System software:
Navigator version G.01.50 or later
Operating System Microsoft Windows NT Server 4.0, Enterprise Edition.
Service pack SP3 with hotfix “clustfixi” or later