HP Netserver LPr NetRAID-4M Config Guide for Windows 2000 Advanced Server Clusters

2
Power source Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDUs) are strongly recommended.
System software:
Navigator version L.20.00 or later
Operating System
Service Pack
Microsoft Windows
2000 Advanced Server
SP1
SPU
Model HP NetServer LPr
Clock speed 850 MHz
No. of CPUs 2 - 6
BIOS version 4.06.35 PR or later
CPU cache Any size
RAM 256 MB minimum. Must be HP.
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind the
servers default boot order as listed below:
Default Boot Order IDE CD-ROM, FDD, Embedded SCSI, PCI-3, PCI-2, PCI-1, PCI-4
Microsoft
and HP
Certified
Configuration
P1 – Shared Storage – NetRAID-4M
P2 – Client LAN – D5013B
P3 – Local Storage – NetRAID-1Si
P4 – Intra-cluster (Heartbeat) LAN
Booted from NetRAID-1Si
Storage
Local
Controller May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M or
NetRAID-2M.
Driver For embedded SCSI, use sym_hi.sys 4.12 or later.
For NetRAID-xSi, use mraid35x.sys version 2.66.
For NetRAID-1M/2M, use mraid2k.sys, version 5.20 or later.
All are from Navigator L.20.00 or later.
Physical drive location SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12)
Disk drives Must be HP
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed
SCSI Ids Any
Shared
Controller
Model HP NetRAID-4M Adapter D9161A or D9351A
No. of controllers 2
BIOS
Disabled
Firmware 4584
Driver Hpn.sys version 2.4.0.4581
NetRAID-4M FAST 2.4-0 or later