hp netserver lxr 8500 netraid-2m config guide for Microsoft NT 4.0 Clusters PDF, 85K, 2/23/2002

lxr8500nt2m
2/23/02 3
Shared Storage Configuration
Parameter Specification
Logical disks One per RAID array
Eight, maximum, per cluster
Configuration options Cluster mode on
Cache write policy to Write thru
Enclosure
Disk drives Any HP drive supported by storage enclosure. Any combination of HP disk
models is allowed in an array, on a SCSI channel, or in a cluster.
Number of cabinets One or two per NetRAID-2M controller (up to four per cluster)
Model HP Rack Storage/12 D5989B, containing two D6025B SCSI controller cards, or
HP Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID 5 (fixed)
Disk SCSI IDs 03, 815 (fixed)
Cables
SCSI Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See SCSI cabling diagram on page 5.
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power cabling
diagram on page 6.
Microsoft
and HP Certified Server Configuration
Parameter Specification
Server
I/O controller PCI slot 1, NetRAID-1M local storage controller
PCI slot 7, NetRAID-2M shared storage controller
Network interfaces PCI slot 3, intra-cluster (heartbeat) LAN
PCI slot 9, client LAN
Boot device NetRAID-1M
Intra-Cluster (Heartbeat) LAN Configuration
Parameter Specification
Network
Connection HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication. It may
not be used for client communication.
NIC
Quantity One